| Grid overview |
| Additional Inputs | 2 Additional Inputs |
| Lock Terminals | 2 Lock Terminals |
| AUX Terminals | 2 AUX Terminals |
| PoE | Nej |
| Overview |
| Dimensions | 140 x 120 x 45 mm
(5.5 x 4.7 x 1.8") |
| Supported Doors | 2 |
| Maximum User Count | 10,000 |
| Input Terminals | (2) Third-party Wiegand Reader / UniFi Retrofit Reader
(2) Door exit request
(2) Door position
(1) Emergency |
| Power Method | 12/24V DC |
| Power Output Availability | Nej |
| NDAA Compliant | Ja |
| UL 294 Level | Destructive attack: Level I
Line security: Level I
Endurance: Level I
Standby power: Level I |
| Mechanical |
| Weight | 420 g (14.8 oz) |
| Enclosure Material | Polycarbonate |
| Mount Material | SGCC steel |
| Mounting | Din-rail (Included) |
| Hardware |
| Digital Input | (2) Third-party Wiegand Reader / UniFi Retrofit Reader
(2) Door exit request
(2) Door position
(1) Emergency |
| Dry Output Relay | Lock: rated 30V DC, up to 1A
Aux: rated 30V DC, up to 1A |
| Wet Output Relay | Nej |
| Powered Output Relay | 12V Lock: 12V DC, up to 1A
24V Lock: 24V DC, up to 0.5A |
| Output Relay | Nej |
| Aux Power Output | Nej |
| Indoor and Outdoor Use | Indoor only |
| Ambient Operating Temperature | -10 to 40° C
(14 to 104° F) |
| Ambient Operating Humidity | 5 to 90% noncondensing |
| Networking Interface | (2) 10/100 MbE RJ45 ports |
| PoE Interface | Nej |
| Total Available PoE | Nej |
| Power Supply | DC 12/24V |
| Max. Power Consumption | 50W |
| Reader Power Output | 12V DC, up to 0.5A |
| Max. PoE Wattage per Port | Nej |
| Battery Charge | Nej |
| LEDs | W/B <a href="https://help.ui.com/hc/en-us/articles/25738084762775-UniFi-Access-Understand-Access-Device-LED-Status-Indicators" target="_blank" rel="noopener noreferrer">Learn More</a> |
| Buttons | (1) Factory reset
(2) 12V/Dry/24V switch |
| Recommend Max. Cable Length: UA-Retrofit-Reader (250mA) | 18 UACC-Cable-DoorLockRelay length: 152.4 m (500 ft) |
| Recommend Max. Cable Length: UA-Lock-Electric
(400mA) | 24 AWG length: 25 m (82 ft)
22 AWG length: 42 m (138 ft)
20 AWG length: 66 m (217 ft)
18 UACC-Cable-DoorLockRelay length: 100 m (328 ft) |
| Recommend Max. Cable Length: UA-Lock-Magnetic-540kg (500mA) | 24 AWG length: 20 m (66 ft)
22 AWG length: 32 m (105 ft)
20 AWG length: 51 m (167 ft)
18 UACC-Cable-DoorLockRelay length: 80 m (262 ft) |
| Recommend Max. Cable Length: UA-Lock-Magnetic-270kg (800mA) | 24 AWG length: 12 m (39 ft)
22 AWG length: 20 m (66 ft)
20 AWG length: 30 m (98 ft)
18 UACC-Cable-DoorLockRelay length: 46 m (151 ft) |
| Recommend Max. Cable Length: Other locks
(1A) | 24 AWG length: 9 m (30 ft)
22 AWG length: 15 m (49 ft)
20 AWG length: 24 m (79 ft)
18 UACC-Cable-DoorLockRelay length: 36 m (118 ft) |
| PoE Cabling Requirements | Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable. |
| UL 294 Statement | Compliance with IEEE 802.3 specifications was not verified as part of UL 294.
The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits. |
| CAN/ULC-60839-11-1 Grade | Grade assignment: I |
| Certifications | CE, FCC, IC, UL 294, CAN/ULC-60839-11-1 |
| Document number, and issue date and/or revision level | UA-Retrofit-Hub-2, V01 |
| Software |
| Management Application | Access |
| Software Information | The software version can be checked at <a href="https://unifi.ui.com/" target="_blank" rel="noopener noreferrer">https://unifi.ui.com</a> |
| Application Requirements: UniFi Protect | Nej |
| Application Requirements: Mobile App | Nej |